Swivel sampler: defined samples directly from the downpipe

Schwenkprobenehmer

RATEC swivel samplers take a defined sample quantity directly from the product stream in a downpipe. A swing arm briefly moves into the stream, diverts the sample to the outside, and then returns to its parked position outside the product stream. The drive is electric or pneumatic; ATEX- and FDA-compliant versions are also available on request, and the swivel samplers can be installed in existing downpipes. RATEC develops and manufactures each unit in-house in St. Veit an der Glan.

How swivel samplers work

  1. Swing in: At the defined time, the swing arm moves into the product stream in the downpipe.
  2. Take: The arm collects a defined sample quantity and diverts it to the outside, for example into a sample bottle or a sample collector.
  3. Park: The arm then returns to its parked position outside the product stream. Until the next sample, the material continues to flow unobstructed.

So the swing arm is only in the product during the actual sampling. The rest of the time it is protected outside the stream, does not obstruct material flow, and is not exposed to constant wear from the bulk material.

Why sample in the downpipe?

In a downpipe, the entire material stream passes a single point, similar to a conveyor belt. This makes it a good location for sampling—for example under a mixer, after a dryer, before a silo, or before filling. Sampling here shows what is actually moving through the process, not just what is on the surface of a silo or at the edge of a container.

At the same time, a downpipe is closed and the material is moving. A manual sample is hardly possible here—and not sensible either. Swivel samplers solve this: they take the sample automatically, always at the same point and in the same quantity. This makes it possible to compare the results of individual samples.

Technical specifications

FeatureRATEC swivel sampler
PrincipleSwivel arm moves into the product stream
Installation locationDownpipe, also retrofittable
Driveelectric or pneumatic
Sample quantitydefined, consistent per sample
Rest positionParked position outside the product stream
Bulk materialspowders, granules, dusts, grains
Can be combined withsample collector, sample transport to the laboratory
VersionsATEX- and FDA-compliant materials on request

Advantages of our swivel samplers

  • Defined sample quantity: every sample is the same size and therefore comparable
  • Only in the product stream during sampling: no obstruction to material flow
  • Automatic return to the parked position: the arm is protected between samples
  • Installation in existing downpipes: ideal for retrofitting
  • Can be automated: electric or pneumatic drive, can be triggered via your control system
  • ATEX and FDA on request: for potentially explosive areas, food and pharma

Retrofitting into existing systems

Many systems have been running for years without automatic sampling, and samples are still taken manually. Our swivel samplers are designed for installation in existing downpipes. So you do not need to modify your system to switch to automatic, reproducible sampling. RATEC adapts the sampler to your line and coordinates with you where and how it is best installed.

Robust, hygienic and easy to operate

Like all RATEC samplers, our swivel samplers are designed for continuous operation in bulk material handling: robust, corrosion-resistant and durable. The units are hygienic and easy to clean, which is particularly important in the food and pharmaceutical industries. No training is required for operation.

Customised by RATEC

RATEC is at home in the bulk solids sector and manufactures components for bulk material systems at its own plant in Carinthia, certified to ISO 9001, EN 1090-1 and ISO 3834-2. Each swivel sampler is designed for your bulk material, your downpipe and your sample quantity—optionally with a sample collector for up to 48 sample containers and sample transport to the laboratory. If a sampling standard such as ISO 11648-2 or an internal test specification applies to your product, we take it into account in the design.

RATEC samplers are used, among other areas, in the chemical industry, the minerals industry, the food and pharmaceutical industries, petrochemicals, the rubber and carbon black industries, animal feed and seed, the wood and paper industry, and recycling. You can find an overview of all designs under Samplers.

Planning sampling from the downpipe?

Briefly describe your bulk material and your downpipe. We will get back to you with a specific solution proposal.

Frequently asked questions

Key factors include bulk material data, downpipe diameter, throughput, installation space, sample volume and frequency, drive type, and ATEX, FDA, or sampling standard requirements. RATEC provides a specific questionnaire for sampling systems to facilitate your inquiry. No flat-rate price is available as each unit is engineered to your specific material and installation site; you will receive a customized quote.

Send inquiry now

Yes, swivel samplers are installed directly into the downpipe and are ideal for retrofitting existing systems. Key factors include pipe cross-section, throughput, and sufficient space for the swivel arm and sample outlet. RATEC custom-engineers devices to fit your piping and determines the optimal installation position. Contact us for a custom quote.

Hardly, because the swivel arm is only in the product stream during sampling and sits outside the line between samples. Material continues to flow unobstructed, and the process does not need to be interrupted. With RATEC swivel samplers, no component remains permanently in the product, reducing wear and build-up.

A swivel sampler uses a swivel arm to extract a defined sample quantity directly from the falling product stream of a downpipe. The arm enters the stream only for sampling, discharges the sample externally, and then returns to its park position. RATEC swivel samplers are electrically or pneumatically driven.

In a falling stream, all material passes a single point, and a swivel arm can traverse the entire cross-section, rather than just sampling from the periphery. This better mitigates segregation effects in bulk material compared to sampling from a static silo. RATEC custom-engineers the swivel path and sample volume to ensure the sample accurately represents your product.